Emerson Process Management Model 2700 Pacemaker User Manual


 
146 Model 2700 Transmitter with PROFIBUS-PA
Slave Diagnostic Response Bytes
Table E-14 Byte 14
Bit Indication
48 Reserved (always set to 0)
49 Reserved (always set to 0)
50 Reserved (always set to 0)
51 Reserved (always set to 0)
52 Reserved (always set to 0)
53 Reserved (always set to 0)
54 Reserved (always set to 0)
55 Extension available
Table E-15 Byte 15
Bit Indication
56 Undefined (A000)
57 EEPROM checksum error (A001)
58 RAM test error (A002)
59 Sensor not responding (no tube interrupt) (A003)
60 Temperature sensor out-of-range (A004)
61 Input over-range (A005)
62 Transmitter not characterized (A006)
63 Reserved
Table E-16 Byte 16
Bit Indication
64 Density outside limits (A008)
65 Transmitter initializing/warming up (A009)
66 Calibration failure (A010)
67 Excess calibration correction, zero too low (A011)
68 Excess calibration correction, zero too high (A012)
69 Process too noisy to perform auto zero (A013)
70 Transmitter failed (A014)
71 Reserved