Table 97: In-system Programming (ISP) hex record formats
Record type Command/data function
00 Program User Code Memory Page
:nnaaaa00dd..ddcc
Where:
nn = number of bytes to program
aaaa = page address
dd..dd= data bytes
cc = checksum
Example:
:100000000102030405006070809cc
01 Read Version Id
:00xxxx01cc
Where:
xxxx = required field but value is a ‘don’t care’
cc = checksum
Example:
:00000001cc
02 Miscellaneous Write Functions
:02xxxx02ssddcc
Where:
xxxx = required field but value is a ‘don’t care’
ss= subfunction code
dd= data
cc = checksum
Subfunction codes:
00= UCFG1
01= reserved
02= Boot Vector
03= Status Byte
04= reserved
05= reserved
06= reserved
07= reserved
08= Security Byte 0
09= Security Byte 1
0A= Security Byte 2
0B= Security Byte 3
0C= Security Byte 4
0D= Security Byte 5
0E= Security Byte 6
0F= Security Byte 7
0A= Clear Configuration Protection
Example: