Mitsubishi Electronics MR-MC211 Sleep Apnea Machine User Manual


 
App. - 15
APPENDIX
(2) Operation from the position board
Positioning operation using the position board is basically the same as operation for using a rotary servo
motor.
However, some parameters, home position return operation, command/status bit, and monitor No. vary
from when using a rotary servo motor. Details are as follows.
(a) Parameters
When using the fully closed loop system, set the parameters shown on the table below.
For other servo parameters, control parameters, and system parameters, set them as equivalent to
using a rotary servo motor.
1) Servo parameters
For details on each parameter, refer to the Servo Amplifier Instruction Manual for your servo amplifier.
<MR-J4(W
)- B>
Parameter
No.
MR-J4-B
Parameter
No.
Abbreviation
(Note)
Name
1100 PA01 **STY Operation mode
1190 PC17 **COP4 Function selection C-4
119A PC27 **COP9 Function selection C-9
1200 PE01 **FCT1 Fully closed loop function selection 1
1202 PE03 *FCT2 Fully closed loop function selection 2
1203 PE04 **FBN Fully closed loop control feedback pulse electronic gear numerator 1
1204 PE05 **FBD Fully closed loop control feedback pulse electronic gear denominator 1
1205 PE06 BC1 Fully closed loop control speed deviation error detection level
1206 PE07 BC2 Fully closed loop control position deviation error detection level
1207 PE08 DUF Fully closed loop dual feedback filter
1209 PE10 FCT3 Fully closed loop function selection 3
1221 PE34 **FBN2 Fully closed loop control feedback pulse electronic gear numerator 2
1222 PE35 **FBD2 Fully closed loop control feedback pulse electronic gear denominator 2
Note. Parameters with asterisk (*) before abbreviation will be valid under the following conditions.
*: After setting, turn off the power supply and then on again, or reset controller.
**: After setting, turn off the power supply and then on again.
2) Control parameters
Parameter
No.
Abbreviation
(Note 1)
Name
Initial
value
Unit
Setting
range
Function
020A *CMXL Electronic gear
numerator (lower)
0001h 1 to
5242879
(32 bit)
(Note2)
Set the numerator of the electronic gear.
(For setting methods, refer to App. 2.4(2)(a)3.)
020B *CMXH Electronic gear
numerator (upper)
0000h
020C *CDVL Electronic gear
denominator (lower)
0001h 1 to
589823
(32 bit)
(Note2)
Set the denominator of the electronic gear.
(For setting methods, refer to App. 2.4(2)(a)3).)
020D *CDVH Electronic gear
denominator (upper)
0000h
021D *VEND Vendor ID 0000h 0000h to
FFFFh
Set the vendor ID.
0000h: Mitsubishi Electric
021E *CODE Type code 1000h 0000h to
FFFFh
Set the type code.
1000h: MR-J4(W
)- B servo amplifier
Note 1. Settings for parameters with asterisk (*) before abbreviation will be valid at system startup.
2. The setting range differs depending on the setting of speed units (parameter No.0200). For details on the setting range, refer to
Section 6.1.1.