8. TANDEM DRIVE
8.4.2 JOG operation during tandem drive
(1) Synchronous mode
When JOG operation is performed while in synchronous mode, master axis data and signals are used.
An example is shown below.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Start of operation Stop operation
Speed (master axis)
Speed (slave axis)
Start operation (ST)
(master axis)
JOG operation mode
(JOG) (master axis)
In JOG operation
mode (JO)
(master axis)
During operation
(OP) (master axis)
During smoothing of
stopping (SMZ)
(master axis)
Important data classifications related to JOG operation during synchronous mode are shown in the
following table. For other related data, refer to Section 10.6.
Type
Items for which only item associated
with master is valid
Items defined for each axis
Command signal/data JOG operation mode (JOG)
Movement direction (DIR)
Start operation (ST)
Manual feed speed
Acceleration time constant
Deceleration time constant
None
Status signal In JOG operation mode (JO)
During operation (OP)
During smoothing of stopping (SMZ)
In-position (INP)
Position switch (PSW)
The in-position signal (INP) is output for each axis separately; therefore, when the axes have come to a
stop and in-position signals are being used, check the in-position signal (INP) for both the master axis and
the slave axis.
For other types of movement, normal axis movement is followed. (Refer to Section 5.1)