Mitsubishi Electronics MR-MC211 Sleep Apnea Machine User Manual


 
6 - 68
6. APPLICATION FUNCTIONS
(b) Details concerning other axes start status bits
Abbreviation Signal name Function details
OSOP Other axes start notice [Function]
Notifies the monitoring for the other axes start condition.
[Operation]
<Conditions for turning on>
The other axis start data is specified in the other axes start specification of the point
table for automatic operation and linear interpolation operation, and the axis is
monitored for the other axes start condition.
<Conditions for turning off>
• The other axes start condition is satisfied.
• During monitoring for the other axes start condition (when OSOP
is on), the other
axes start cancel signal (OSSTP
) is turned on.
OSFIN Other axes start complete [Function]
Notifies that the other axes start operation content is executed.
[Operation]
<Conditions for turning on>
The other axes start condition is satisfied, and the other axes start operation content is
executed.
<Conditions for turning off>
The other axes start data is specified in the other axes start specification in the point
table for automatic operation or linear interpolation operation.
OSERR Other axes start incomplete [Function]
Notifies that the other axes start has failed.
[Operation]
<Conditions for turning on>
• The axis specified in the start axis designation is being operated when the other
axes start operation content should be executed.
• The operation mode of the axis specified in the start axis designation is other than
automatic operation and linear interpolation operation when the other axes start
operation content should be executed.
• During monitoring for the other axes start condition (when OSOP
is on), operation
is canceled due to an operation alarm on the axis or the (rapid) stop operation signal
((R)STP) turned on.
• During monitoring for the other axes start condition (when OSOP
is on), the other
axes start cancel signal (OSSTP
) is turned on.
• The number of axes set in the start axis designation exceeds the maximum number
of simultaneous start axes.
<Conditions for turning off>
The other axes start data is specified in the other axes start specification in the point
table for automatic operation or linear interpolation operation.
Note. : Other axes start No.