Mitsubishi Electronics MR-MC211 Sleep Apnea Machine User Manual


 
6 - 89
6. APPLICATION FUNCTIONS
6.29.3 Interface
(1) Pass position interrupt table
The pass position condition (pass position option and pass position data) is set to the pass position
interrupt table.
The pass position condition is imported when the corresponding pass position condition number is started
to be judged.
POINT
When the pass position condition setting is incorrect, a pass position interrupt
error (operation alarm 5C, detail 04) occurs and the operation is stopped.
API LIBRARY
Use the sscSetIntPassPositionData/sscCheckIntPassPositionData functions
to set/get pass position interrupt data.
Pass position interrupt table
A640h Pass position condition 1
(8 bytes)
Pass position option
Pass position data
A648h
Pass position condition 2
(8 bytes)
Pass position option
Pass position data
A650h
Pass position condition 3
(8 bytes)
Pass position option
Pass position data
A658h
Pass position condition 4
(8 bytes)
Pass position option
Pass position data
A660h
Pass position condition 5
(8 bytes)
Pass position option
Pass position data
A668h
Pass position condition 6
(8 bytes)
Pass position option
Pass position data
A670h
Pass position condition 7
(8 bytes)
Pass position option
Pass position data
A678h
Pass position condition 8
(8 bytes)
Pass position option
Pass position data
A680h
Pass position condition 9
(8 bytes)
Pass position option
Pass position data
A688h
Pass position condition 10
(8 bytes)
Pass position option
Pass position data
A690h
Pass position condition 11
(8 bytes)
Pass position option
Pass position data
A698h
Pass position condition 12
(8 bytes)
Pass position option
Pass position data
A6A0h
Pass position condition 13
(8 bytes)
Pass position option
Pass position data
: :
A838h
Pass position condition 64
(8 bytes)
Pass position option
A83Fh Pass position data