Mitsubishi Electronics MR-MC211 Sleep Apnea Machine User Manual


 
11 - 34
11. PARAMETERS
Parameter
No.
Symbol Name
Initial
Value
Units
Setting
range
Function
When tandem
drive is being
used
0282 *IOP2 Interference
check
Options 2
0000h
0000h to
0011h
00
Interference check direction
Set the direction for which
interference check is performed.
0: direction of coordinate
system for the axis
1: direction of coordinate
system for the axis
Interference check standby
Set validity/invalidity of
interference check standby.
0: Invalid
1: Valid
Master
0283
For
manufacturer
setting
0
0284 IOFL Interference
check Offset
(lower)
0000h
Command
Units
0000h to
FFFFh
Set the position on the home position standard
coordinate system.
Master
0285 IOFH Interference
check Offset
(upper)
0000h
0000h to
FFFFh
0286 IWL Interference
check width
(lower)
0000h
Command
Units
0000h to
FFFFh
Set the width from the interference check axis target
position of the area where interference check is
performed.
Master
0287 IWH Interference
check width
(upper)
0000h
0000h to
7FFFh
0288
For
manufacturer
setting
0
0289
0
028A
0
028B
0
028C
0
028D
0
028E 0
028F 0
: :
02AF 0
02B0 *MKOP1 Mark
detection
option 1
0000h 0000h to
3F23h
Mark detection signal number
specification 1
Set the mark detection signal number
to be used.
0 : Invalid
1 to 3: Mark detection signal number
(DI1 to DI3)
Mark detection mode
Set the mark detection mode
0: Continuous detection
1: Specified number of detection
2: Ring buffer
Number of continuous latch data
storages (Note)
Set the number of data that can be
latched continuously.
00h to 3Fh: Number of continuous
latch data storages-1
Note. Up to 64 can be set in the
whole system.
Each axis