Mitsubishi Electronics MR-MC211 Sleep Apnea Machine User Manual


 
6 - 101
6. APPLICATION FUNCTIONS
(2) When the pass position interrupt fails
When the operation is canceled due to an operation alarm preceding the satisfaction of the pass position
condition, the pass position interrupt incomplete (PPIERR) turns on. The pass position interrupt incomplete
(PPIERR) turns on under the following conditions.
At this time, the factor of interrupt of the "pass position interrupt error condition
" ( : pass position
condition number) turns on to the running and unexecuted pass position interrupt conditions and the
interrupt is output.
(a) The setting of the pass position condition is incorrect.
(b) Operation is canceled by turning on the stop operation signal (STP) or the rapid stop signal (RSTP)
before the pass position condition is satisfied.
(c) Operation is canceled by an operation alarm, etc. before the pass position condition is satisfied.
(d) Operation is completed and the in-position signal is turned on before the pass position condition is
satisfied.
[Example of when an operation alarm occurs]
Operation alarm occurrence
Pass position interrupt
(PPIOP)
Pass position interrupt
complete (PPIFIN)
Pass position interrupt
incomplete (PPIERR)
During operation (OP)
Start operation (ST)
Operation alarm (OALM)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
In-position (INP)
ON
OFF
Pass position condition
start number
1
Running pass position
condition number
0 1
Pass position condition
end number
2
Pass position interrupt incomplete 1
Pass position interrupt incomplete 2