Invacare 2GT Wheelchair User Manual


 
SECTION 11—CENTER MOUNT FOOTRESTS
2G Tarsys®Powered Seating System 120 Part No 1114842
Adjusting the Height of the Center Mount Footrest
ƽ WARNING
After adjusting the Center Mount Footrest, minimum ground clearance for the
footrest in the driving position is three inches. If the Center Mount Footrest is in the
retracted position and the wheelchair is not moving, the footrest must maintain a
minimum of one inch ground clearance. Otherwise personal injury and damage may
result.
NOTE: For this procedure, refer to FIGURE 11.2.
1. Remove the two mounting screws that secure the footrest extension tube to the
extension tube housing.
2. If adjusting to one of the three shortest settings for footrest height, remove the
retaining ring on the angle adjustment pin and slide it out.
3. Adjust the footrest extension tube to the desired height and align the corresponding
holes to the mounting holes on the extension tube housing.
4. If adjusting to one of the three shortest settings for footrest height, install the angle
adjustment pin and the retaining ring.
5. Reinstall the two mounting screws to secure the footrest extension tube to the
extension tube housing. Securely tighten.
6. Repeat STEPS 1-5 for the other extension tube.
FIGURE 11.2 Adjusting the Height of the Center Mount Footrest
Release Lever
Seat Frame
Extension Tube Housing
Height Adjustment Holes
Mounting Screws
Extension Tube Mounting Holes
Extension Tube
Retaining Ring
Angle Adjustment Pin