Emerson 1500 Pacemaker User Manual


 
Transmitter default values and ranges (continued)Table D-1:
Type Parameter Default Range Comments
Fault action Downscale
AO fault level – downscale 2.0 mA 1.0 – 3.6 mA
AO fault level – upscale 22 mA 21.0 – 24.0 mA
Last measured value timeout 0.00 sec
LRV Mass flow rate
200.000 g/s
Volume flow rate
0.200 l/s
Density 0.000 g/cm
3
Temperature
240.000 °C
Drive gain 0.000%
Gas standard volume flow rate
423.78SCFM
External temperature
240.000 °C
External pressure 0.000 psi
URV Mass flow rate 200.000 g/s
Volume flow rate 0.200 l/s
Density 10.000 g/cm
3
Temperature 450.000 °C
Drive gain 100.000%
Gas standard volume flow rate 423.78SCFM
External temperature 450.000 °C
External pressure 100.000 psi
Frequency out-
put
Tertiary variable Mass flow
Frequency factor 1,000.00 Hz 0.001 – 10,000
Hz
Flow rate factor 1000 kg/min
Frequency pulse width 277.0 ms 0 or 0.5 –
277.5 ms
Scaling method Freq=Flow
Frequency fault action Downscale
Frequency fault level – upscale 15,000 Hz 10.0 – 15,000
Hz
Frequency output polarity Active high
Last measured value timeout 0.0 seconds 0.0 – 60.0 sec
Discrete out-
put
Source Flow direction
Fault Indicator None
Power Internal
Polarity Active high
Default values and ranges
238 Micro Motion
®
Model 1500 Transmitters with Analog Outputs