Emerson 1500 Pacemaker User Manual


 
Transmitter default values and ranges (continued)Table D-1:
Type Parameter Default Range Comments
Density units g/cm
3
Density cutoff 0.2 g/cm
3
0.0 – 0.5 g/cm
3
D1 0 g/cm
3
D2 1 g/cm
3
K1 1000 µsec 1000 – 50,000
µsec
K2 50,000 µsec 1000 – 50,000
µsec
FD 0
Temp Coefficient 4.44
Slug flow Slug flow low limit 0.0 g/cm
3
0.0 – 10.0 g/
cm
3
Slug flow high limit 5.0 g/cm
3
0. 0 – 10.0 g/
cm
3
Slug duration 0.0 sec 0.0 – 60.0 sec
Temperature Temperature damping 4.8 sec 0.0 – 80 sec User-entered value is corrected
to nearest lower value in list of
preset values.
Temperature units Deg C
Temperature calibration factor 1.00000T0.00
00
Pressure Pressure units PSI
Flow factor 0
Density factor 0
Cal pressure 0
T-Series sensor D3 0 g/cm
3
D4 0 g/cm
3
K3 0 µsec
K4 0 µsec
FTG 0
FFQ 0
DTG 0
DFQ1 0
DFQ2 0
Special units Base mass unit g
Base mass time sec
Mass flow conversion factor 1
Base volume unit L
Default values and ranges
236 Micro Motion
®
Model 1500 Transmitters with Analog Outputs