Emerson 2200S Pacemaker User Manual


 
Configuration and Use Manual 91
Operating the Transmitter
Operation AppendicesMaintenance and TroubleshootingCommissioning
1. To view totalizer values, wait or Scroll until the process variable TOTAL appears and the units
of measure are:
For the mass totalizer, mass units (e.g., kg, lb)
For the volume totalizer, volume units (e.g., gal, cuft, scf, nm3)
See Figure 8-1. Read the current value from the top line of the display.
2. To view inventory values, wait or
Scroll until the process variable TOTAL appears and:
For the mass inventory, the word
MASSI (Mass Inventory) begins to alternate with the
units of measure
For the volume inventory, the word
LVOLI (Line Volume Inventory) begins to alternate
with the units of measure
For gas volume inventory, the word
GSVI (Gas Standard Volume Inventory) begins to
alternate with the units of measure
See Figure 8-1. Read the current value from the top line of the display.
Figure 8-1 Totalizer values on display
With ProLink II
To view current totals for the totalizers and inventories with ProLink II:
1. Click
ProLink.
2. Select
Process Variables or Totalizer Control.
With the Communicator
To view current totals for the totalizers and inventories with the Communicator:
1. Select
Process Variables > View fld dev vars.
2. Scroll through the list of process variables by pressing
Down Arrow.
3. Press the number corresponding to the totalizer or inventory you wish to view, or highlight it in
the list and press
Right Arrow.
Current value
Unit of measure
Process variable
Scroll button