Emerson 2200S Pacemaker User Manual


 
92 Micro Motion
®
Model 2200S Transmitters
Operating the Transmitter
8.7.2 Controlling totalizers and inventories
Table 8-1 shows all of the totalizer and inventory functions and which configuration tools you can use
to control them.
With the display
Table 8-2 shows how you can control the totalizers and inventories with the display.
Table 8-1 Totalizer and inventory control methods
Function name Display Communicator ProLink II
Start/stop all totalizers and inventories Yes
(1)
(1) If enabled. See Section 5.2.4.
Ye s Ye s
Reset mass totalizer value only Yes
(1)
Ye s Ye s
Reset volume totalizer only Yes
(1)
Ye s Ye s
Simultaneously reset all totalizer values Yes
(1)
Ye s Ye s
Simultaneously reset all inventory values No No Yes
(2)
(2) If enabled in the ProLink II Preferences window.
Reset mass inventory value only No No Yes
(2)
Reset volume inventory value only No No Yes
(2)
Table 8-2 Totalizer and inventory control with the display
To accomplish this Press this sequence of buttons
Stop all totalizers and
inventories
(1)
(1) This feature may be enabled or disabled. See Section 5.2.4.
Scroll until a totalizer value appears (the word TOTAL appears in the lower left corner of
the display). It does not matter whether the total is mass or volume.
• Select.
Scroll until STOP appears beneath the current totalizer value.
Select (
YES alternates with STOP).
Select (all totalizers and inventories stop).
Scroll to
EXIT.
Start all totalizers and
inventories
(1)
Scroll until a totalizer value appears (the word TOTAL appears in the lower left corner of
the display). It does not matter whether the total is mass or volume.
• Select.
Scroll until
START appears beneath the current totalizer value.
Select (
YES alternates with START).
Select (all totalizers and inventories start).
Scroll to
EXIT.
• Select.
Reset mass totalizer
(1)
Scroll until the mass totalizer value appears.
Select.
Scroll until
RESET appears beneath the current totalizer value.
Select (
YES alternates with RESET).
Select (mass totalizer resets).
Scroll to
EXIT.
Select.
Reset volume (liquid or
gas) totalizer
(1)
Scroll until the volume totalizer value appears.
Select.
Scroll until RESET appears beneath the current totalizer value.
Select (
YES alternates with RESET).
Select (volume totalizer resets).
Scroll to EXIT.
Select.