Emerson 2200S Pacemaker User Manual


 
Configuration and Use Manual 55
Configuring Operational Parameters
Operation AppendicesMaintenance and TroubleshootingCommissioning
Configuration
To enable and disable display functions:
Using the Communicator, select
Detailed Setup > Display Setup.
Using ProLink II, click ProLink > Configuration > Display.
Using the display, see Figure 2-14.
5.3 Configuring fault handling
The Model 2200S transmitter performs self-diagnostics during operation. If the device detects certain
events or conditions, the configured fault handling is implemented. Fault handling may include:
Performing the mA output fault action and the digital communications fault action, and
showing alarm information on the display
Posting an alarm to the active alarm log
Status alarm severity controls which of these methods is used.
Last measured value timeout is used to delay the mA output fault action, for certain faults only. The
digital communications fault action is always performed immediately.
5.3.1 Status alarm severity
Status alarms are classified into three levels of severity. The severity level controls transmitter
behavior when the alarm condition occurs. See Table 5-4.
Example
Case 1: Operators do not need to know which alarms are active.
There are no special requirements for configuring Auto Scroll and
Alarm Menu. The display will indicate when alarms are active.
Information on specific alarms can be retrieved via the Communicator,
ProLink II, or the host.
Case 2: Operators must be able to view the list of active alarms at the
device. Operators are allowed to remove the transmitter housing cover.
There are no special requirements for configuring Auto Scroll and
Alarm Menu. The display will indicate when alarms are active, and the
operator can use the alarm menu to see the list of specific alarms.
Case 3: Operators must be able to view the list of active alarms at the
device. Operators are not allowed to remove the transmitter housing
cover.
To configure this functionality:
1. Enable Auto Scroll.
2. Enable Alarm Menu.