NCT Group 99M Microscope & Magnifier User Manual


 
20 Custom Macro
168
20.4 Custom Macro Call Using M Code
Maximum 10 different M codes can be selected by parameters, to which macro calls are initiated.
Now the series of instructions
Nn Mm <argument assignment>
have to be typed. Now code M will not be transferred to the PLC, but the macro of the respective
program number will be called.
The particular program number to be called by the calling M code has to be selected by parameters.
M(9020)=code M calling program O9020
M(9021)=code M calling program O9021
:
M(9029)=code M calling program O9029
Code M can specify invariably a type G65 call (i.e., a non-modal one).
If reference is made again to the same M code in the middle of the macro body, the latter will not
call the macro, instead, M code will be transferred to the PLC.
If a user call type G, S, T, A, B, C or some other user call type M is made in the middle of the
macro body,
FGMAC=0, not enabled (executed as ordinary M, S, ... G codes)
FGMAC=1, enabled, i.e. a new call is generated.
An M code selected by parameters to initiate a macro call may be preceded only by "/" and address
N in the block.
A block containing a macro call initiated by M code may include a single M code only.
Set of arguments No.1:
A B C D E F G H I J K L P Q R S T U V W X Y Z
Set of arguments No. 2 also can be used with function M.
20.5 Subprogram Call with M Code
Maximum 10 M codes can be selected by parameters, by which subprogram calls can be initiated.
Now instead of instruction
Nn Gg Xx Yy M98 Pp
can be specified
Nn Gg Xx Yy Mm
Now the selected M code will not be transferred to the PLC, instead, the respective subprogram
will be called.
The particular program number to be called by M code can be selected by the following
parameters.
M(9000)=code M calling program O9000
M(9001)=code M calling program O9001
:
M(9009)=code M calling program O9009
If reference is made to the same M code again in the subprogram, the latter will not call the
subprogram again, but M code will be transferred to the PLC.
If a user call G, S, T, A, B, C or some other user call M is made in the subprogram:
FGMAC=0, not enabled (executed as an ordinary codes M, S, ... G)