Lucent Technologies 7820-0802-003 Wheelchair User Manual


 
Configuring the Thermal Profile for Fan Tray Operations (APX 8000)
Thermal status reporting
APX 8000/MAX TNT/DSLTNT Physical Interface Configuration Guide Preliminary May 9, 2000 3-5
Thermalstatus command
The thermalstatus command displays a number of temperature-related values to show
the overall thermal status of the unit. For example, it displays:
Ambient temperature at fan tray intake.
Shelf controller temperature.
High, Low, and Alarm temperature thresholds.
Slot card temperature for slot cards that support temperature reporting. Currently, no slot
cards support thermal information reporting.
Power supply thermal status, and whether the power supplies are in an overheated state.
Fan tray status, including the fan tray operational mode, number of revolutions per minute
at low-noise speed, and current revolutions per minute of each fan.
For example:
admin> thermalstatus
System Thermal status
Ambient temperature at intake : 27 C (80 F)
Shelf controller temperature : 35 C (95 F)
High temperature threshold : 36 C (96 F)
Low temperature threshold : 32 C (89 F)
Alarm temperature threshold : 38 C (100 F)
Slot cards:
(no slot cards contain thermal information)
Power supply thermal status
Power Supply # Temp
=================================
A OK
B OK
C n/a
D OK
Fantray status
Fan operational mode: auto-regulation
Low-noise RPM: 2000
Current fan mode: Full-speed
Fan # RPM Status
============================================
1 3289 GOOD
2 3214 GOOD
3 3075 GOOD
4 3143 GOOD
5 3214 GOOD
6 3289 GOOD