Configuring DSL Connections (DSLTNT)
Sample DSL configurations
APX 8000/MAX TNT/DSLTNT Physical Interface Configuration Guide Preliminary May 9, 2000 17-29
2 Specify the following values:
Chan Usage=Leased/Unused
My Name=dslpipe
My Addr=10.10.73.1/24
Rem Name=max-tnt
Rem Addr=104.178.115.163/24
Route=IP
Bridge=No
3 From the Main Edit menu, select Ethernet > Connections > max-tnt.
4 Specify the following values:
Active=Yes
Encaps=PPP
Bridge=No
Route IP=Yes
5 Open the Encaps Options submenu.
6 Specify the following values:
Send Auth=PAP
Send PW=PAP
Recv PW=PAP
Link Comp=None
VJ Comp=No
7 Open the Telco Options submenu.
8 Specify the following values:
Call Type=Nailed
Group=1
9 Exit the Connection profile and save your changes.
Sample SDSL Frame Relay configuration using numbered interfaces
This section describes a common SDSL application. In this example, the SDSL line is a leased
connection over a single pair of wires, using Frame Relay as the transport protocol (see
Figure 17-5). The example uses interface-based routing on a point-to-point link. Each side of
the connection is assigned a unique address that applies only to the connection.
This example uses SDSL, but you can configure an ADSL connection similarly.