Lucent Technologies 7820-0802-003 Wheelchair User Manual


 
Performing Basic Configuration
Connecting to a new unit
APX 8000/MAX TNT/DSLTNT Physical Interface Configuration Guide Preliminary May 9, 2000 1-3
Connecting to a new unit
To communicate with a new TAOS unit, you must assign an IP address to the shelf controller.
Once this is done, you can perform further configuration over a LAN using Telnet.
Use the following procedures to connect a new TAOS unit, if you have not already done so,
and assign an Ethernet IP address.
New APX 8000 unit
Use the following procedure to initially set up an APX 8000 unit:
1 Connect a PC terminal or workstation to the serial port on the shelf controller (see the APX
8000 Hardware Installation Guide). If the APX 8000 is equipped with redundant shelf
controllers, connect to the serial port on the primary controller.
2 Connect an Ethernet cable between the network and the Ethernet port on the shelf
controller (see the APX 8000 Hardware Installation Guide). If the APX 8000 is equipped
with redundant shelf controllers, connect to the Ethernet port on the primary controller.
3 Configure an IP address and network mask in the ip-interface profile.
For an APX 8000 unit with one shelf controller, see Configuring the shelf-controller
IP address on a nonredundant unit on page 1-4.
For an APX 8000 unit with redundant shelf controllers, see Assigning an Ethernet IP
address on page 2-4.
4 Verify that the connection and IP address are correct by pinging any device on the
network.
5 If redundant controllers are used, set the secondary and soft IP addresses (see Assigning
an Ethernet IP address on page 2-4 and Defining the soft IP interface for fault tolerance
on page 2-5 for details).
6 Exit the terminal or workstation.
7 Telnet from a workstation on the LAN. The system will prompt you for the username and
password.
User: admin
Password: Ascend
8 Complete the configuration.
New MAX TNT or DSLTNT unit
Use the following procedure to initially set up a MAX TNT or DSLTNT unit:
1 Connect a PC terminal or workstation to the serial port on the shelf controller (see the
MAX TNT/DSLTNT Hardware Installation Guide). Ensure that the speed is set to
9600 bps.
2 Connect an Ethernet cable to the network and to the Ethernet port on the shelf controller
(see the MAX TNT/DSLTNT Hardware Installation Guide).
3 Configure an IP address and network mask in the ip-interface profile (see
Configuring the shelf-controller IP address on a nonredundant unit on page 1-4).