17-30 Preliminary May 9, 2000 APX 8000/MAX TNT/DSLTNT Physical Interface Configuration Guide
Configuring DSL Connections (DSLTNT)
Sample DSL configurations
Figure 17-5. Example SDSL setup with interface-based routing
Configuring an SDSL connection requires the following general steps:
Configuring the Connection profile
Configuring an IP-Route profile
Configuring the SDSL profile
Configuring the Frame-Relay profile
Configuring the DSLPipe-S
Configuring the Connection profile
To configure the Connection profile:
1 Create a new Connection profile:
admin> new connection sdsl-pipeline
2 Enable the profile:
admin> set active=yes
3 Specify the encapsulation type as Frame Relay:
admin> set encapsulation-protocol=frame-relay
4 List the IP-Options submenu:
admin> list ip-options
[in CONNECTION/sdsl-pipeline:ip-options]
ip-routing-enabled = yes
vj-header-prediction = yes
remote-address = 0.0.0.0/0
local-address = 0.0.0.0/0
..
..
5 Set the IP address of the DSLPipe-S connecting to the DSLTNT:
admin> set remote-address=192.168.23.141/30
6 Set the IP address of the DSLTNT SDSL port:
DSLPipe address
192.168.23.141/30
local loop (SDSL)
COE (MAX TNT)
CPE (DSLPipe-S)
192.168.216.1/24
SDSL port address
192.168.23.142/30
LAN Adrs= 192.168.23.141/30
WAN Alias=0.0.0.0