Mitsubishi Q68TD-G-H02 Thermometer User Manual


 
3 - 40
3.4 Buffer Memory
3.4.4 Conversion completion flag (Un\G10)
3
SPECIFICATIONS
3.4.4 Conversion completion flag (Un\G10)
Conversion state can be checked for each channel.
(1) Data storage
(a) The bit of the corresponding channel in Conversion completion flag turns on
(changes to “1”) when conversion of conversion-enabled channels is completed.
Figure 3.22 Storage of Conversion completion flag (Un\G10)
(b) Conversion completion flag (XE) turns on when conversion of all conversion-
enabled channels is completed.
(2) How to clear stored data
When Operating condition setting request (Y)) is turned on, the bit of all channels in
the Conversion completion flag returns to default value (“0”).
POINT
Use this area or Conversion completion flag (XE) as an interlock to read out the
measured temperature value.
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
CH8 CH7 CH6 CH5 CH4 CH3 CH2 CH100000000
Data for b8 to b15 are fixed to "0".
0: During conversion or unused
1: Conversion completed