(2) Applicable thermocouples, conversion accuracy, and effect from wiring
resistance of 1Ω
The following table lists applicable thermocouples, conversion accuracy, and the
effect from wiring resistance of 1Ω.
Table 3.2 Applicable thermocouples, conversion accuracy, and the effect from wiring resistance of 1Ω
Usable
Thermo
couple
Type
Measured
Temperature
Range
*1
Conversion Accuracy
(At operating ambient
temperature 25 5 )
Temperature Characteristic
(Per operating ambient
temperature variation of
1 )
Max. Temperature
Error at Ambient
Temperature 55
Effect from wiring
resistance of 1
Ω
*4
(upper: Q68TD-G-H02
lower: Q68TD-G-H01)
B
0 to 600
------
*3
------
*3
------
*3
------
*3
600 to 800
*2
3.0
0.4
13.0
-0.169 /Ω
-0.042 /Ω
800 to 1700
*2
2.5 12.5
-0.143 /Ω
-0.036 /Ω
1700 to 1820
------
*3
------
*3
------
*3
------
*3
R
-50 to 0
------
*3
------
*3
------
*3
------
*3
0 to 300
*2
2.5 0.4 12.5
-0.200 /Ω
-0.050 /Ω
300 to 1600
*2
2.0 0.3 9.5
-0.112 /Ω
-0.028 /Ω
1600 to 1760
------
*3
------
*3
------
*3
------
*3
S
-50 to 0
------
*3
------
*3
------
*3
------
*3
0 to 300
*2
2.5 0.4 12.5
-0.200 /Ω
-0.050 /Ω
300 to 1600
*2
2.0 0.3 9.5
-0.112 /Ω
-0.028 /Ω
1600 to 1760
------
*3
------
*3
------
*3
------
*3
K
-270 to -200
------
*3
------
*3
------
*3
------
*3
-200 to 0
*2
Larger value of 0.5 and
0.5% of measured
temperature
Larger value of 0.06 and
0.2% of measured
temperature
11.0
-0.034 /Ω
-0.009 /Ω
0 to 1200
*2
Larger value of 0.25
and
0.5% of measured
temperature
Larger value of 0.06 and
0.02% of measured
temperature
9.0
-0.026 /Ω
-0.007 /Ω
1200 to 1370
------
*3
------
*3
------
*3
------
*3
E
-270 to -200
------
*3
------
*3
------
*3
------
*3
-200 to 0
*2
Larger value of 0.5 and
0.5% of measured
temperature
Larger value of 0.06 and
0.15% of measured
temperature
8.5
-0.023 /Ω
-0.006 /Ω
0 to 900
*2
Larger value of 0.5 and
0.25% of measured
temperature
Larger value of 0.06 and
0.02% of measured
temperature
6.75
-0.018 /Ω
-0.005 /Ω
900 to 1000
------
*3
------
*3
------
*3
------
*3
J
-210 to -40
------
*3
------
*3
------
*3
------
*3
-40 to 750
*2
Larger value of 0.5 and
0.25% of measured
temperature
Larger value of 0.06 and
0.02% of measured
temperature
5.625
-0.022 /Ω
-0.006 /Ω
750 to 1200
------
*3
------
*3
------
*3
------
*3