5
UTILITY PACKAGE (GX Configurator-TI)
5.1 Utility Package Functions
5 - 2
1
OVERVIEW
2
SYSTEM
CONFIGURATION
3
SPECIFICATIONS
4
SETUP AND
PROCEDURES BEFORE
OPERATION
5
UTILITY PACKAGE (GX
CONFIGURATOR-TI)
6
PROGRAMMING
7
ONLINE MODULE
CHANGE
8
TROUBLESHOOTING
* 1 The parenthetic name is for the Q68TD-G-H01 and the other is for the Q68TD-G-H02.
* 2 The cold junction compensation setting state is only for the Q68TD-G-H02.
Monitor/
test
Monitors and tests the buffer memory and I/O signals for the Q68TD-G-H
02(H01).
Section 5.6
•Module ready •Disconnection detection signal (Disconnection state
monitor signal)
*1
•Operating condition setting completion flag
•Operating condition setting request •Warning output signal
•Offset/gain setting mode status flag •Conversion completion flag
•User range write request •Error flag
•Channel change completion flag •Error clear request
•Channel change request
•Cold junction compensation setting state
*2
(1)
CH Monitor/test
•Conversion enable/disable setting •Warning output flag (Rate alarm) upper limit value
•Averaging processing selection •Rate alarm upper limit value
•Time/count/moving average/time constant setting •Rate alarm lower limit value
•Conversion completion flag •Disconnection detection flag (Disconnection state
monitor flag)
*1
•Measured temperature value
•Error code •Scaling value
•Thermocouple type •Scaling valid/invalid setting
•Warning output enable/disable setting (Process alarm)
•Scaling range lower limit value
•Warning output flag (Process alarm) lower limit value •Scaling range upper limit value
•Warning output flag (Process alarm) upper limit value •Scaling width lower limit value
•Process alarm lower lower limit value •Scaling width upper limit value
•Process alarm lower upper limit value •Scaling value
•Process alarm upper lower limit value •Conversion setting for disconnection detection
(Disconnection state conversion setting)
*1
•Process alarm upper upper limit value
•Warning output enable/disable setting (Rate alarm)
•Conversion setting value for disconnection
detection (Conversion setting value for
disconnection state)
*1
•Rate alarm warning detection period
•Warning output flag (Rate alarm) lower limit value
(2) Offset/Gain Setting
•Mode switching setting
•CH Offset setting value
•Mode switching setting status
•CH Gain setting channel setting
•Conversion enable/disable setting
•CH Gain setting value
•Operating condition setting request
•CH Channel change request
•CH Thermocouple type •CH Offset temperature setting value
•CH Offset setting channel setting
(3) X/Y Monitor/Test
•Xn0: Module ready •Yn9: Operating condition setting request
•Xn9: Operating condition setting completion flag •YnA: User range write request
•XnA: Offset/gain setting mode status flag •YnB: Channel change request
•XnB: Channel change completion flag •YnF: Error clear request
•XnC: Disconnection detection signal (Disconnection
state monitor signal)
*1
•XnD: Warning output signal
•XnE: Conversion completion flag
•XnF: Error flag
(4) OMC refresh
•CH Factory default offset/gain value
•CH User range settings offset/gain value
•CH User range settings thermal EMF offset/gain value
•OMC Refresh data read request
•OMC Refresh data write request
Table 5.1 Utility Package (GX Configurator-TI) Function List
Function Description
Reference
section