Mitsubishi Q68TD-G-H02 Thermometer User Manual


 
7 - 20
7.3 Online Module Change Procedure
7.3.4 When user range setting is used and initial setting was made with GX Configurator-TI (other system
7
ONLINE MODULE CHANGE
(b) Click the button to enable a module change.
Figure 7.36 "Online module change" screen
If the following error screen appears, the user range cannot be saved. Click the
button, and perform the operation in Section 7.3.4 (2)(c) and later.
Figure 7.37 Error screen
(c) After confirming that the "RUN" LED of the module has turned off, remove the
connector and dismount the module.
POINT
Always dismount the module. If you execute mounting confirmation without
dismounting the module, the module will not start properly and the "RUN" LED will
not be lit.
(3) Mounting of new module
(a) Mount a new module to the same slot, and install the connector.
(b) After mounting the module, click the button and make sure that the
"RUN" LED is lit. Module ready (X0) remains OFF.
Figure 7.38 "Online module change" screen