Samsung 7100 Medical Alarms User Manual


 
CHAPTER 2. Ошибка! Стиль не определен.
2-16
Samsung Business Communications
[108] STATION STATUS
This is a READ-ONLY MMC. Displays the following attributes of a station port.
No Status Description
0 PORT NO Cabinet(1)/Slot(MP,1,2)/Port(1-12)
1 TYPE Phone Type
2 PICKUP GROUP None, 01-99
3 SGR Station Group Number
4 BOSS-SECR None, 1-4
5 PAGE None, Page Zone(0-4, * )
6 COS 1, COS 2 COS(1-30) per Ring Plan(01-06)
DEFAULT DATA
PORT #: FOLLOWS HARDWARE POSITION
TYPE: DEPENDENT ON CONNECTED PHONE
PICKUP GRP: NONE
SGR: NONE
BOSS-SECR: NONE
PAGE ZONE: NONE
COS NUMBER: 01 IN ALL RING PLANS
ACTION DISPLAY
1) Press Transfer button and enter 108.
Display shows first station:
[201] STN STATUS
PORT:C1-S1-P01
2) Dial station number.(e.g., 205)
OR
[205] STN STATUS
PORT:C1- S1-P05
Press Volume button to select station and
press Right Soft button to move cursor.
3) Dial 0~9 to select station status type.
OR
[205] STN STATUS
PICKUP GROUP:01
Press Volume button to select status and
press Right Soft button to return to step 2.
4)
Press Transfer button to save and exit.
OR
Press Speaker button to save and advance to
next MMC.