Samsung 7100 Medical Alarms User Manual


 
CHAPTER 2. Ошибка! Стиль не определен.
2-96
Samsung Business Communications
[323] CALLING PARTY NUMBER
Allows a number up to 16 digits to be entered and associated with a station or trunk num-
ber on a per PRI/BRI basis. When this station makes an outgoing call on this PRI, the
number entered here will be the Calling Party Number sent on the call. There are four ta-
bles for the system. If there are no entries in the tables the system uses the number for the
trunk entered in MMC 405, TRUNK CO TEL NUMBER, for the Calling Party Number.
DEFAULT DATA
EMPTY
ACTION DISPLAY
1) Press Transfer button and enter 323.
Display shows:
[201] SEND CLIP
1:
2) Dial extension or trunk number.(e.g., 230)
OR
[230] SEND CLIP
1:
Press Volume button to select extension and
press Right Soft button to move the cursor.
3) Dial table number.
OR
[230] SEND CLIP
2:
Press Volume button to select table number and
press Right Soft button to move the cursor.
4) Enter the Calling Party Number.
[230] SEND CLIP
2:3055922900
5) Repeat steps 3 & 4 to enter other tables and Calling
Party Numbers.
OR
Repeat steps 2, 3, & 4 to enter other station or trunk
and Calling Party Numbers.
6) Press Transfer button to save and exit.
OR
Press Speaker button to advance to next MMC.
RELATED ITEMS
MMC 419 BRI OPTIONS
MMC 420 PRI OPTIONS
MMC 834 H.323 OPTIONS