Samsung 7100 Medical Alarms User Manual


 
OfficeServ 7100 Call Server Programming Guide
Samsung Business Communications 2-141
[501] SYSTEM TIMERS
Allows the technician to adjust individual timers as necessary.
TIMER TABLE
Timer Name Default Range Unit Description
ALARM TIME 100 0-2500 MIN This is the time the system alarm key will start
ringing after the alarm key has been silenced.
ALERT TONE TIME 1000 100-2500
MSEC
This timer sets the duration of the attention
tone preceding a call to a phone in the Voice
Announce or Auto Answer mode. This tone
will also precede a forced Auto Answer call.
ALM REM.INTERVAL 25 1-250 SEC This timer controls the time between ring at-
tempts at a station when alarm reminder is
set.
ALM REM RING OFF 10 1-25 SEC This timer controls the length of the ring cycle
duration when an alarm reminder is set at a
station.
ATT. RECALL TIME 30 0-250 SEC This controls how long a transfer recall will
ring at a station before recalling the operator.
AUTO REDIAL INT. 30 1-250 SEC This timer controls the time between attempts
after RETRY dialling is set on a station.
AUTO REDIAL RLS. 45 1-250 SEC This timer controls the duration of a Ring No
Answer condition on a retry number dialled
before the auto redial is automatically can-
celled.
BOOTH TIME OUT
(Hotel application only)
005 0-250 MIN Controls the time for which a booth phone is
enabled.
CALLBACK NO ANS 30 1-250 SEC This timer controls the time before the call-
back is automatically cancelled when a call-
back detects Ring No Answer.
CAMP ON RECALL 30 0-250 SEC This timer controls the time a camped-on call
will stay at a destination before recalling to the
transferring station.
CID MSG RECEIVE 6 1-25 SEC The amount of time that the system will allow
a valid message from the analogue CID trunk.
CLI DISPLAY TIME 5 1-25 SEC The amount of time that the Caller ID informa-
tion remains on the phone’s display.
CO CLEAR TIME 30 0-250 SEC The length of time a Direct Trunk Select key
remains busy after cleardown.