Samsung 7100 Medical Alarms User Manual


 
OfficeServ 7100 Call Server Programming Guide
Samsung Business Communications 2-311
No Parameter Description Default
13 GRQ SEND Select ON or OFF for use of Gatekeeper RAS Re-
quest(GRQ) messages.
OFF
14 USE MULTI E.164 When this option is set to ENABLE, the E.164 identi-
fier can be assigned.
DISABLE
15 E.164 LISTS This is the E.164 identifier used by the H.323 trunk
when registering with the gatekeeper. There is a
maximum 32 E.164 identifier lists with a digit string
length of 16 digits.
NONE
16 GK REGISTERED Display the status of registration to the Gatekeeper.
NO
DEFAULT DATA
SEE DESCRIPTION
ACTION DISPLAY
1) Press Transfer button and enter 836.
Display shows the first available option.
GK CONNECTION
DISABLE
2) Enter H.323 GK option via dial keypad.
OR
GK ROUTING
DISABLE
Press Volume button to make selection and
press Right Soft button to move cursor.
3) Enter H.323 GK option data.
OR
GK ROUTING
ENABLE
Press Volume button to make selection and
press Right Soft button to save and return step 3.
4) Press Transfer button to save and exit.
OR
Press Speaker button to advance to next MMC.
RELATED ITEMS
MMC 834 H.323 OPTIONS