Samsung 7100 Medical Alarms User Manual


 
OfficeServ 7100 Call Server Programming Guide
Samsung Business Communications 2-257
[759] CLI RINGING
This MMC assigns a specific CID number received from the central office to a specific
ring plan destination. Also allows you to reject a specific CID number and assign priorities.
There are 9 priority levels: priority 1 is the highest and priority 9 is the lowest.
It also allows you to select the ring tone heard at a phone when called by a specific CID number.
There is also a cadence control option to perform a similar function for SLTs. There are eight ring
tones available along with a Follow Station(NO) option. There are five cadences and a Follow
Station option(NO) for SLTs. The CID Ringing table consists of 100 entries.
DEFAULT DATA
NONE
Option Description
CLI CID number to be received from the central office. Up to 16 digits may be
entered.
REJ CID call reject option. When this sets YES, if a call comes that matched CID
number and CLI field then the system will be reject call.
PRI CID priority option. There are 9 priority levels: priority 1 is the highest and
priority 9 is the lowest. When calls into station group come and group mem-
bers are all busy, the system will assign a priority to the CID number so that
calls from a high priority CID number will be placed at the front of the group
queue.
If this option sets NO, the longest call that placed at the group queue has
the highest priority.
R1: XXX, R2: XXX,
R3: XXX, R4: XXX,
R5: XXX, R6: XXX
Ring plan and destination during each ring plan. The destination can be a
station, station group.
Ring Tone options for a specific CID Number.(NO, 1~8)
No Calls will ring with the phone users choice of ring frequency.
TONE
1~8 Calls from the programmed CID number will ring phones with this
ring frequency.
Ring Cadence options for a specific CID Number at SLT’s(NO, 1~5)
No Calls will ring with the normal SLT ring cadences.
1 Calls from the programmed CID number will ring SLT’s with the intercom
ring cadence.
2 Calls from the programmed CID number will ring SLT’s with the CO ring
cadence.
3 Calls from the programmed CID number will ring SLT’s with the DOOR
ring cadence.
4 Calls from the programmed CID number will ring SLT’s with the ALARM
ring cadence.
CAD
5 Calls from the programmed CID number will ring SLT’s with the CALL-
BACK ring cadence.