Samsung 7100 Medical Alarms User Manual


 
CHAPTER 2. Ошибка! Стиль не определен.
2-348
Samsung Business Communications
[856] TECH PROGRAMMING LOGS
This MMC lists the date, time and entry location of the last eight times that technician-
level programming was accessed. This allows a technician to determine if there was unau-
thorized access to system programming and where this access occurred. The information
stored in this log is displayed, for each of the eight accesses, as follows: first line shows the
start date and time of access; second line shows the access type(see table) and end date and
time of access.
There are four access types:
Type Description
NNNN The extension number of a phone that accessed programming directly(e.g., 3203)
MODEM Programming was accessed by PCMMC via the integrated V90 modem attached to
the IOM board of the main cabinet.
LAN Programming was accessed by PCMMC via the LAN connection on the MCP2 card
of main cabinet.
SIOx Programming was accessed by PCMMC via one of the SIO connections on the IOM
board of the main cabinet, where x is the number(2 or 3) of the SIO port that was
used.
DEFAULT DATA
NONE
ACTION DISPLAY
1) Press Transfer button and enter 856.
Display shows:
(1) 11/22 11:03Æ
3203 :11/22 11:27
2) Enter number 1-8 for required access display.
(e.g., 3)
(3) 11/22 12:30Æ
3203 :11/22 13:30
OR
Press Volume button to scroll.
3) Press Transfer button to save and exit.
OR
Press Speaker button to advance to next MMC.
RELATED ITEMS
MMC 800 ENABLE TECHNICIAN PROGRAM