Samsung 7100 Medical Alarms User Manual


 
CHAPTER 2. Ошибка! Стиль не определен.
2-340
Samsung Business Communications
(continued)
No Code Alarm Name Definition
- MJD-- DTRK Error ISDN or E1 card Fault
33 MJD01 Sync Failure Clocking on TEPRI cards has become asynchronous.
34 MJD02 Sync Recovery Clocking on TEPRI cards has become synchronous.
35 MJD03 Red Alarm Locally detected loss of PCM carrier on TEPRI card for
more than 250 ms.
Alarm Data = Cabinet, Slot(Cx-Syy)
36 MJD04 Red Alarm Rec PCM carrier detected locally on TEPRI cards.
Alarm Data = Cabinet, Slot(Cx-Syy)
37 MJD05 Yellow Alarm Remotely detected failure transmitted in frame on
TEPRI card.
Alarm Data = Cabinet, Slot(Cx-Syy)
38 MJD06 Yellow Alarm
Rec
Remotely detected failure restored transmitted on
TEPRI card.
Alarm Data = Cabinet, Slot(Cx-Syy)
39 MJD07 Blue Alarm All 1's being transmitted on facility on TEPRI card.
Alarm Data = Cabinet, Slot(Cx-Syy)
40 MJD08 Blue Alarm Rec A blue alarm condition has been cleared.
Alarm Data = Cabinet, Slot(Cx-Syy)
41 MJD09 Bit Error Alarm Alarm is activated when the error rate exceeds 1 x 10
-6
errors. Note: 1x10
-6
is threshold for minor alarm, 1 x 10
-3
is
threshold for major alarm errors on E1, PRI or BRI.
Alarm Data = Cabinet, Slot(Cx-Syy)
42 MJD10 NTWRK Event An Implausible event has occurred on the PRI or BRI
Network digital line. Protocols do not match or sub-
scriber ID mismatch.
Alarm Data = Cabinet, Slot(Cx-Syy)
43 MJD11 SPID Init Error The BRI received an error from the network.
Alarm Data = Cabinet, Slot, Channel(Cx-Syy-czz)
44 MJD12 SPID Init Rec The BRI has recovered from an error on the network
Alarm Data = Cabinet, Slot, Channel(Cx-Syy-czz)
45 MJD13 LPBK Error Internal on demand loopback failed.
Alarm Data = Cabinet, Slot, Channel(Cx-Syy-czz)
46 MJD14 LPBK Recovery Internal on demand loopback test passed.
Alarm Data = Cabinet, Slot, Channel(Cx-Syy-czz)
47 MJD15 BRI DL Unavail A BRI data link is out of service.
Alarm Data = Cabinet, Slot, Channel(Cx-Syy-czz)
48 MJD16 BRI DL Recovery A BRI data link is back in service.
Alarm Data = Cabinet, Slot, Channel(Cx-Syy-czz)
49 MJD17 RAM Error An error has occurred in the TEPRI or BRI card RAM.
Alarm Data = Cabinet, Slot(Cx-Syy)