Samsung 7100 Medical Alarms User Manual


 
CHAPTER 2. Ошибка! Стиль не определен.
2-156
Samsung Business Communications
[507] ASSIGN RING PLAN TIME
Use this MMC to program Ring Plans time settings. Ring Plans provide six separate ring-
ing destinations based on day of the week and time of day. The start time within a plan is
the time the system will switch from one ringing destination to the next. The end time is the
time the system will switch from that plan to the previous plan.
An RPO(Ring Plan Override) button is not needed as the system will switch automatically;
however, it is helpful to have a dedicated button so the status can be manually changed if
needed. If a ring plan has no time entry the ring plan defaults to ring plan 1. The ring plans
correlate with all MMCs that program ring or termination destinations and station and
trunk COS.
The following example may be useful when assigning ring plan times:
RING PLAN Start Time End Time
(MON: 1) ST: 0000 END: 23:59
(MON: 2) ST: 0800 END: 2200
(MON: 3) ST: 1000 END: 2000
(MON: 4) ST: 1200 END: 1800
(MON: 5) ST: 1300 END: 1600
(MON: 6) ST: 1400 END: 1500
Using a 24-hour clock in the example above, notice that the END time is within the same
24-hour period as the START time. The system will stay in the last active Ring Plan from
the previous day until the end time which is 23:59. Monday starts Ring Plan 1 at 00:00.
The system will stay in Ring Plan 1 until Ring Plan 2 starts(08:00) and will stay in Ring
Plan 2 until Ring Plan 3 starts(10:00), and so on. As each ring Plan start it will override the
previous Ring Plan.
If a Ring Plan expires and there are no additional Ring Plans set, the system will default to
the Ring Plan with a time that extends past the expired Ring Plan time.
CONDITIONS
y When using a Samsung built-in Voice Mail card that only has day/night mode, the
day/night must be set for each RING PLAN in MMC 758, VM DAY/NIGHT.
y Ring Plans must be programmed in sequence.(RP 1, 2, 3, 4, etc.) A Ring Plan cannot
be omitted.(i.e. you cannot program RP 1, 2, 5, etc.)
y A higher numbered Ring Plan cannot have a START time which begins before a lower
numbered Ring Plan.