Mitsubishi Electronics BNP-B2203D Blood Glucose Meter User Manual


 
Appendix 2 Cable Manufacturing Drawings
80
Appendix 2 Cable Manufacturing Drawings
Cable type name table
No. Appendix No. Cable type Application Max. length Remarks
1 Appendix 2.1 SH21 cable Servo drive unit * 30m
2 Appendix 2.2 SH41 cable Remote I/O * 50m
3 Appendix 2.3 R031 cable Analog input/output 30m
4 Appendix 2.4 R041 cable Manual pulse generator: 1ch 50m
5 Appendix 2.5 R042 cable Manual pulse generator: 2ch 50m
6 Appendix 2.6 R211 cable Remote I/O * 50m
7 Appendix 2.7 R220 cable DC +24V input, emergency stop 30m
8 Appendix 2.8 R300 cable DI/DO: Single-end connector 50m
9 Appendix 2.9 R301 cable DI/DO: Double-end connector 50m
10 Appendix 2.10 F010 cable I/O interface: Base I/O unit 20m
11 Appendix 2.11 F011 cable I/O interface: Relay card 15m
12 Appendix 2.12 F020 cable Manual pulse generator: 1ch 50m
13 Appendix 2.13 F021 cable Manual pulse generator: 2ch 50m
14 Appendix 2.14 F022 cable Manual pulse generator: 3ch 50m
15 Appendix 2.15 F040 cable Spindle encoder: Straight * 50m
16 Appendix 2.16 F041 cable Spindle encoder: Right angle * 50m
17 Appendix 2.17 F070 cable DC +24V input, emergency stop 30m
18 Appendix 2.18 F390 cable RS232C: 1ch 15m
19 Appendix 2.19 ENC-SP1 cable Spindle drive unit 50m
* For the cables marked with * in the Max. length column:
The cable length (L1) is the length from the NC Card to the base I/O unit and relay card. The cable
length (L2) is the length from the base I/O unit and relay card to each unit. Keep the total cable length
(L1 + L2) within the maximum cable length.
SV1
SV2
RIO1
RIO2
ENC1
F010
L2
L1
SH21
SH41
(R211)
F040/041
F011
ENC#2
F040/041
NC card
Relay card
Servo drive unit
Spindle encoder
Spindle encoder
Base I/O unit
Remote I/O unit
Maximum cable length
Symbols for writing cable manufacturing drawing
The following symbols are used in the cable manufacturing drawing.
1.
indicates twist.
2.
indicates the shield sheath.
3.
indicates shield clamping to the ground plate.
4. In the cable manufacturing drawings, the partner of the twisted pair cable is given a priority, so the pin Nos. of the
connectors at both end are not necessary in number of order.
5. Equivalent parts can be used for the connector, contact and wire material.