Appendix 2 Cable Manufacturing Drawings
2.9 R301 Cable (Machine input/output)
90
Cable type name: R301 cable Appendix 2.9
Application: Base I/O unit and remote I/O unit
– Recommended terminal block
Assembly drawing
(2)
R301
R301
(1)
(1)(3)
Base I/O unit and
remote I/O unit side
The No.1 pin cable is colored.
Maximum cable length: 50m
Recommended terminal block side
Manufacturing precautions
(1) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used
providing they are compatible with the specifications.
(2) Attach the nameplate with protective cover stamped with the cable name in the position
designated in the assembly drawing.
(3) The recommended terminal block is the IDEC IZUMI I/O terminal BX1F-T40.
Option (compatible connector set)
FCUA-CS301
List of parts used
No. Part name Recommended part type Qty
1 Connector
Sumitomo 3M
7940-6500SC
2
2
Wire
material
Oki Electric Cable
B40-S
(1)
3 Strain relief
Sumitomo 3M
3448-7940
1