7. Remote I/O Unit Connection (FCUA-DX1**)
7.5 Outline of Digital Signal Output Circuit
56
7.5 Outline of Digital Signal Output Circuit
The digital signal output circuit uses a sink type (DX1*0) or source type (DX1*1). Use within the
specification ranges shown below.
Output circuit
+24VDC
RA
R
PL
Source type (DX1*1)
R
(Machine side)
Control
circuit
Sink type (DX1*0)
RA
PL
DO-R/DO-L
DO-R/DO-L
+24VDC
Control
circuit
(Machine side)
Output conditions
Insulation method Non-insulation
Rated load voltage +24VDC
Max. output current 60mA/1 point (fixed value)
Output delay time 40µs
(Note) An output voltage of more than 60mA per point cannot be flowed.
When using an inductive load such as a relay, always connect a diode in parallel to the
load.
When using a capacity load such as a ramp, always connect a protective resistor serially
to the load to suppress rush currents.
* When using an inductive load such as a relay, always connect a diode (voltage
resistance 100V or more, 100mA or more) in parallel to the load.
* When using a capacity load such as a ramp, always connect a protective resistor
(R=150 ) serially to the load to suppress rush currents. (Make sure that the
current is less than the above tolerable current including the momentary current.)
<CAUTION>
CAUTION