2. Configuration
2.2 List of Configuration Units
4
2. I/O unit (2)
Type
Configuration
elements
Details
RX323-1 DI (sink/source)/DO (sink)=32/16 RX323-1 Add-on PCB
RX323 DI (sink/source)/DO (sink)=32/16
Analog output 1 point
RX323 Add-on PCB
RX324-1 DI (sink/source)/DO
(source)=32/16
RX324-1 Add-on PCB
RX324 DI (sink/source)/DO
(source)=32/16
Analog output 1 point
RX324 Add-on PCB
RX331 Manual pulse generator 2ch RX331 Add-on PCB
RX341 Analog input 4 points,
Analog output 1 point
RX341 Add-on PCB
FCUA-DX100 DI (sink/source)/DO (sink)=32/32 RX311 Base PCB: DI (sink/source)/DO (sink)=32/32
Case
RX311 Base PCB: DI
(
sink/source
)
/DO
(
sink
)
=32/32
RX321-1 Add-on PCB: DI
(
sink/source
)
/ DO
(
sink
)
=32/16
FCUA-DX110 DI (sink/source)/DO (sink)=64/48
Case
RX311 Base PCB: DI
(
sink/source
)
/DO
(
sink
)
=32/32
RX321 Add-on PCB: DI (sink/source)/ DO (sink)=32/16
Analo
g
out
p
ut 1
p
oint
FCUA-DX120 DI (sink/source)/DO (sink)=64/48
Analog output 1 point
Case
RX311 Base PCB: DI
(
sink/source
)
/DO
(
sink
)
=32/32
RX331 Add-on PCB: Manual
p
ulse
g
enerator 2ch
FCUA-DX130 DI (sink/source)/DO (sink)=32/32
Manual pulse 2ch
Case
RX311 Base PCB: DI
(
sink/source
)
/DO
(
sink
)
=32/32
RX341 Add-on PCB: Analog input 4 points,
analo
g
out
p
ut 1
p
oint
FCUA-DX140 DI (sink/source)/DO (sink)=32/32
Analog input 4 points,
Analog output 1 point
Case
RX312 Base PCB: DI
(
sink/source
)
/DO
(
source
)
=32/32FCUA-DX101 DI (sink/source)/
DO (source)=32/32
Case
RX312 Base PCB: DI
(
sink/source
)
/DO
(
source
)
=32/32
RX322-1 Add-on PCB: DI
(
sink/source
)
/ DO
(
source
)
=32/16
FCUA-DX111 DI (sink/source)/
DO (source)=64/48
Case
RX312 Base PCB: DI
(
sink/source
)
/DO
(
source
)
=32/32
RX322 Add-on PCB: DI (sink/source)/ DO (source)=32/16
Analo
g
out
p
ut 1
p
oint
FCUA-DX121 DI (sink/source)/
DO (source)=64/48
Analog output 1 point
Case
RX312 Base PCB: DI
(
sink/source
)
/DO
(
source
)
=32/32
RX331 Add-on PCB: Manual
p
ulse
g
enerator 2ch
FCUA-DX131 DI (sink/source)/
DO (source)=32/32
Manual pulse 2ch
Case
RX312 Base PCB: DI
(
sink/source
)
/DO
(
source
)
=32/32
RX341 Add-on PCB: Analog input 4 points,
analo
g
out
p
ut 1
p
oint
FCUA-DX141 DI (sink/source)/
DO (source)=32/32
Analog input 4 points,
Analog output 1 point
Case
3. Peripheral devices
Type
Configuration
elements
Details
HD60C Manual pulse generator Without MELDAS logo
HD60C-1 Manual pulse generator With MELDAS logo
Grounding plate D Grounding plate D set
Grounding plate E Grounding plate E set
4. Operation unit options
Type
Configuration
elements
Details
FCU6-HR211 I/O branch plate HR211 card
FCU6-HR251 IC card interface HR251 card