3. Installation
3.3 Installation
8
3.3 Installation
3.3.1 Installation Direction and Spacing
Each unit is installed in a sealed structure electric cabinet as a principle. Observe the following points
when installing into the electric cabinet.
(1) Install each unit vertically, so that it is visible from the front.
(2) Consider the heat radiation and wiring of each unit. Refer to the following drawing, and secure
space for ventilation.
(3) Install the personal computer main unit paying particular attention to the specification conditions of
the selected personal computer.
MITSUBISHI
MITSUBISHI
RI02
RI01
DCIN
0 0
CF31 CF32
CF34CF33
CF10
SV2
SV1
SKIP
ENC1
CR31
EM G1
HANDLE
RS232C
ENC#2
CF61
EM G2
DCIN
Relay card
Base I/O unit
Remote I/O unit
Servo drive unit
Spindle drive unit
30mm or more
10mm
or more
10mm
or more
10mm or more
10mm
or more
10mm or more
150mm or more
(heat radiation and
wiring space)
15mm or more
(wiring space)
15mm or more
(wiring space)
Top
Bottom
100mm or more
(heat radiation space)
(Note) The relay card can be added on to the base I/O unit. Refer to "6.6 Installation to the Base I/O
Unit" for the installation method when adding on.
Always observe the direction of installation.
CAUTION