Mitsubishi Electronics BNP-B2203D Blood Glucose Meter User Manual


 
3. Installation
3.1 General Specifications
5
3. Installation
3.1 General Specifications
NC Card peripheral environment conditions
Type name HR621/HR623 FCU6-HR655 HR682
Unit name NC Card Relay card
During operation 0~55°C
Ambient
temperature
During storage -20~60°C
During operation 40~75% RH (with no dew condensation)
Ambient
humidity
During storage 40~75% RH (with no dew condensation)
Working atmosphere No corrosive gas or dust
General
specifications
– 3.3VDC ± 5%
5VDC ± 2%
Power voltage
12VDC ± 2%
24VDC ± 5%
Ripple ± 5% (P-P)
3.3V – 0.2A (max) –
5V 2.5A (max)
12V 0.5A (max) 0.7A (max)
Current
consumption
24V – 0.5A (max)
Power specifications
Power drop characteristics Personal computer 5V: 4.5V
4.0V is 1ms or more (*1)
Heating value 19W 22W 12W
Unit size 248.9×107.6×20 (mm)
174.63×106.68×21
(mm)
115×156×30 (mm) (*2)
(*1) If these characteristics are not satisfied, the NC Card cannot back up the absolute position information of
the machine position when the power is turned OFF.
(*2) Excluding spacers
Environmental conditions in electric cabinet
Type name FCU6-DX210, FCU6-DX211 FCU6-DX220, FCU6-DX221
Unit name Base I/O unit
During operation 0~55°C
Ambient
temperature
During storage -20~60°C
During operation 45~75% RH (with no dew condensation)
Ambient
humidity
During storage 45~80% RH (with no dew condensation)
Vibration resistance 4.9m/s
2
or less (during operation)
Shock resistance 29.4m/s
2
or less (during operation)
General specifications
Working atmosphere No corrosive gas or dust
Power voltage
24VDC ± 5%
Ripple ± 5% (P-P)
Current consumption 5V 1A (max), 24V 3.6A (max) (*3) 5V 1A (max), 24V 4.8A (max) (*3)
Power
specifications
Heating value 90W (*3) 110W (*3)
Mass 2.0kg
Unit size 220×168×35 (mm)
(*3) When all DO points are ON