Mitsubishi Electronics BNP-B2203D Blood Glucose Meter User Manual


 
5. Base I/O Unit Connection
5.3 Base I/O Unit Part Names
34
List of rotary switches
No. Name Function
(14)
CS1 This is used in the station No. setting of the CF31 and CF33 machine input/output signals.
(15)
CS2 This is used in the station No. setting of the CF32 and CF34 machine input/output signals.
Device assignment
Rotary switch
setting value
Station
No.
DI DO
0 0 X00~X1F Y00~Y1F
1 1 X20~X3F Y20~Y3F
2 2 X40~X5F Y40~Y5F
3 3 X60~X7F Y60~Y7F
4 4 X80~X9F Y80~Y9F
5 5 XA0~XBF YA0~YBF
6 6 XC0~XDF YC0~YDF
7 7 XE0~XFF YE0~YFF
8~F Cannot be used
LED list
No. Name Function
24IN This is the LED for the 24VDC input display.
When lit (green) : 24VDC being supplied.
When not lit : 24VDC supply OFF.
(16)
RAL1
This is the LED for the onboard remote I/O 1st station
(CS1 setting station No.) communication alarm display.
When lit (red) : Communication alarm.
When not lit : Normal
5OUT
This is the LED for the circuit power 5VDC output
display.
When lit (green) : Outputting 5VDC.
When not lit : 5VDC output OFF.
(17)
RAL2
This is the LED for the onboard remote I/O 2nd station
(CS2 setting station No.) communication alarm display.
When lit (red) : Communication alarm.
When not lit : Normal