Mitsubishi Electronics BNP-B2203D Blood Glucose Meter User Manual


 
Appendix 2 Cable Manufacturing Drawings
2.18 F390 Cable (RS232C)
99
Cable type name: F390 cable Appendix 2.18
Application: Relay card – RS-232C device connection (cross cable)
Assembly drawing
(1)(2)(3)
(4)
F390
F390
(1)(2)(3)
Relay card side
Connector name: RS232C
RS-232C device side
Connector name: CH1
Connection diagram
2
3
4
5
6
20
7
3
2
4
5
6
20
7
FG
RS232C
SD
RD
ER
DR
GND
CH1
Manufacturing precautions
(1) The wire material shall be a shielded, 6-pair stranded cable equivalent to AWG24 (0.2mm
2
).
(2) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used
providing they are compatible with the specifications.
(3) Attach the nameplate with protective cover stamped with the cable name in the position
designated in the assembly drawing.
(4) Fold the wire material shield on the base I/O unit and relay card side over the sheath, and
wrap copper foil tape over it.
Connect the wound copper foil tape to the connector's GND plate.
List of parts used
No. Part name Recommended part type Qty
1 Connector
Hirose Electric
CDB-25P
2
2 Contact
Hirose Electric
CD-PC-111
14
3
Connector
case
Hirose Electric
HDB-CTH
2
4
Wire
material
Bando Electric Wire
DPVVSB 6P × 0.2 mm
2
(1)