Appendix 2 Cable Manufacturing Drawings
2.14 F022 Cable (Manual pulse generator)
95
Cable type name: F022 cable Appendix 2.14
Application: Relay card – Manual pulse generator connection
(when three manual pulse generators are connected)
Assembly drawing
(1)(2)(3)
(4)
(5)
F022
F022
F022
Relay card side
Manual pulse generator side
F022
Connection diagram
1
2
10
9
3
4
12
11
5
6
14
13
1HA
1HB
+12V
GND
2HA
2HB
+12V
GND
3HA
3HB
+12V
GND
1ch
Relay card side
Manual pulse generator side
2ch
Maximum cable length: 50m
3ch
Case frame
FG
Manufacturing precautions
(1) The wire material shall be a shielded, 6-pair stranded cable equivalent to AWG22 (0.3mm
2
).
(2) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used
providing they are compatible with the specifications.
(3) Attach the nameplate with protective cover stamped with the cable name in the position
designated in the assembly drawing.
(4) Fold the wire material shield on the relay card side over the sheath, and wrap copper foil tape
over it. Connect the copper foil tape wrapped around the sheath to a connector GND plate.
(5) Stamp the name of each signal on the crimp terminal side mark tube and install.
List of parts used
No. Part name Recommended part type Qty
1 Connector
Hirose Electric
CDA-15P
1
2 Contact
Hirose Electric
CD-PC-111
12
3
Connector
case
Hirose Electric
HAD-CTH
1
4
Wire
material
Sumitomo Electric
B-22 (19) U × 2SJ-1 × 9
(6)
5
Crimp
terminal
J.S.T. Mfg
V1.25-3
12