Mitsubishi Electronics BNP-B2203D Blood Glucose Meter User Manual


 
6. Relay Card (HR682) Connection
6.1 Relay Card Outline
44
6. Relay Card (HR682) Connection
6.1 Relay Card Outline
The relay card is used in the connection of the spindle encoder, manual pulse generator, RS-232C and
external emergency stop.
There must be one relay card for each NC Card.
Name Type
No. of machine input/
output points
Other interfaces
Relay
card
HR682 No DI/DO
EMG, ENC#2, HANDLE 3ch and
RS-232C.
With metal spacers. Add-On to
FCU6-DX2** possible.
RS-232C uses only the DC code
(X ON/OFF) method handshake.
6.2 Relay Card Connection System Diagram
CF61
ENC#2
HANDLE
RS232C
EMG1
DCIN
CF61
NC Card
F011 cable
Relay card
Encoder 2ch (2nd spindle encoder)
Manual pulse generator 3ch
RS-232C 1ch
Emergency stop switch
External power (24VDC)
F040 cable
F020 cable
F070 cable
F070 cable
F390 cable