Appendix 2 Cable Manufacturing Drawings
2.11 F011 Cable (NC Card)
92
Cable type name: F011 cable Appendix 2.11
Application: NC Card – Relay card connection
Assembly drawing
(1)(2)
(1)(2)
(3)
F011
F011
Connection diagram
TD0
RD0
LED1
LED2
LED3
EMGOUT*
EMGIN
EMGIN*
GND
GND
HA1A
HA1B
HA2A
HA2B
HA3A
HA3B
DR0
DC0
GND
GND
EN2A
EN2A*
EN2B
EN2B*
EN2Z
EN2Z*
1
14
2
15
3
16
4
17
5
18
6
19
7
20
8
21
9
22
10
23
11
24
12
25
13
26
FG
FG
1
14
2
15
3
16
4
17
5
18
6
19
7
20
8
21
9
22
10
23
11
24
12
25
13
26
Case frame Case frame
Maximum cable length: 15m
Manufacturing precautions
(1) The wire material shall be a shielded, 15-pair stranded cable equivalent to UL20276 Standard
AWG28 (0.08mm
2
).
(2) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used
providing they are compatible with the specifications.
(3) Attach the nameplate with protective cover stamped with the cable name in the position
designated in the assembly drawing.
(4) Fold the wire material shield over the sheath, and wrap copper foil tape over it. Connect the
copper foil tape wrapped around the sheath to a connector GND plate.
(5) Part No. 1 (plug) and part No. 2 (shell) are solderless types. If soldering types are required,
use parts equivalent to 10126-3000VE for the plug and 10326-52FO-008 for the shell (both
parts manufactured by Sumitomo 3M).
List of parts used
No. Part name Recommended part type Qty
1 Plug
Sumitomo 3M
10126-6000EL
2
2 Shell
Sumitomo 3M
10326-3210-000
2
3
Wire
material
Toyokuni Electric Cable
UL20276 AWG28 × 15P