Mitsubishi Electronics BNP-B2203D Blood Glucose Meter User Manual


 
Appendix 2 Cable Manufacturing Drawings
2.10 F010 Cable (NC Card)
91
Cable type name: F010 cable Appendix 2.10
Application: NC Card – Base I/O unit connection
Assembly drawing
(1)(2)
(1)(2)
(3)
F010
F010
Connection diagram
TXRX1
TXRX1*
TXRX2
TXRX2*
GND
GND
SKIP1
SKIP1*
SKIP2
SKIP2*
SKIP3
SKIP3*
SKIP4
SKIP4*
SKIP5
SKIP5*
SKIP6
SKIP6*
SKIP7
SKIP7*
SKIP8
SKIP8*
GND
GND
ENC1A
ENC1A*
ENC1B
ENC1B*
ENC1Z
ENC1Z*
GND
GND
SVTXD2
SVTXD2*
SVALM2
SVALM2*
SVRXD2
SVRXD2*
SVEMG2
SVEMG2*
GND
GND
SVTXD1
SVTXD1*
SVALM1
SVALM1*
SVRXD1
SVRXD1*
SVEMG1
SVEMG1*
1
26
2
27
3
28
4
29
5
30
6
31
7
32
8
33
9
34
10
35
11
36
12
37
13
38
14
39
15
40
16
41
17
42
18
43
19
44
20
45
21
46
22
47
23
48
24
49
25
50
1
26
2
27
3
28
4
29
5
30
6
31
7
32
8
33
9
34
10
35
11
36
12
37
13
38
14
39
15
40
16
41
17
42
18
43
19
44
20
45
21
46
22
47
23
48
24
49
25
50
FG FG
Maximum cable length: 20m
Case frame
Case frame
List of parts used
No. Part name Recommended part type Qty
1 Plug
Sumitomo 3M
10150-6000EL
2
2 Shell
Sumitomo 3M
10350-321-000
2
3
Wire
material
Toyokuni Electric Cable
UL20276 AWG28 × 25P
(1)
Manufacturing precautions
(1) The wire material shall be a shielded,
25-pair stranded cable equivalent to
UL20276 Standard AWG28
(0.08mm
2
).
(2) The parts used shall be Mitsubishi
recommended parts. Equivalent parts
may be used providing they are
compatible with the specifications.
(3) Attach the nameplate with protective
cover stamped with the cable name in
the position designated in the
assembly drawing.
(4) Fold the wire material shield over the
sheath, and wrap copper foil tape ove
r
it. Connect the copper foil tape
wrapped around the sheath to a
connector GND plate.
(5) Part No. 1 (plug) and part No. 2 (shell)
are solderless types. If soldering types
are required, use parts equivalent to
10150-3000VE for the plug and
10350-52FO-008 for the shell (both
parts manufactured by Sumitomo 3M).