Emerson Rosemount 8732 Oxygen Equipment User Manual


 
Reference Manual
00809-0100-4665, Rev AA
August 2010
Rosemount 8732
A-10
IECEx
Standard Standard
EF
IECEx flameproof Ex de IIB T6 Gb and IECEx Dust Approval; Ex de [ia IIC Ga] IIB T6 Gb with IS
Output
NF Ex tD A20 IP66 T100 °C or Ex tD A20 IP66 T100 °C [Ex ia Ga] IIC
Expanded
E7 IECEx flameproof Ex de IIC T6 Gb and IECEx Dust Approval; Exde [ia Ga] IIC T6 Gb with IS Output
N7 Ex nA nL IIC T4 and IECEx Dust; Ex nA nL [ia] IIC T4 with FISCO/FNICO outputs
NEPSI and CMC (China)
Standard Standard
EP NEPSI flameproof Ex de IIB T6; Ex de [ia] IIB T6 with IS output
Expanded
E3 NEPSI flameproof Ex de IIC T6; Ex de [ia] IIC T6 with IS output
InMetro (Brazil)
Standard Standard
EB InMetro flameproof BR-Ex de IIB T6; BR- Ex de [ia] IIB T6 with IS outputs
Expanded
E2 InMetro flameproof BR-Ex de IIC T6; BR- Ex de [ia] IIC T6 with IS outputs
GOST (Russia) 8732E
Standard Standard
EM GOST flameproof EX de IIB T6; Ex de [ia] IIB T6 with IS outputs
Expanded
E8 GOST flameproof Ex de IIC T6; Ex de [ia] IIC T6 with IS outputs
KOSHA (Korea)
Standard Standard
EK KOSHA flameproof EX de IIB T6; Ex de [ia] IIB T6 with IS outputs
Expanded
E9 KOSHA flameproof Ex de IIC T6; Ex de [ia] IIC T6 with IS outputs
Options (Include with selected model number)
PlantWeb Product/Process Diagnostics
Standard Standard
D01 Magmeter digital fieldbus Diagnostic Suite 1: High Process Noise and Ground/Wiring Fault Detection
D02 Magmeter digital fieldbus Diagnostic Suite 2: SMART Meter Verification
Other Options
Standard Standard
M4 Local Operator Interface
Expanded
C1 Custom Configuration (CDS Required)
D1 High Accuracy Calibration (0.15% of rate for matched sensor and transmitter)
(3)
DT Heavy Duty Tagging
B6 316L Stainless Steel 4-bolt Kit for 2-in. Remote Pipe Mount
GE M12, 4-Pin, Male Connector (Eurofast)
GM A Size Mini, 4-Pin, Male Connector (Minifast)
GT A Size, Spade Terminal Mini, 5-pin, Male Connector (Minifast)
Q4 Inspection certificate; calibration data, ISO10474 3.1B
QIG Language
8732E
Expanded
YA Danish
YB Hungarian
YC Czech
YD Dutch
YE Bulgarian
YF French
Table A-1. Rosemount 8732E/ Profibus PA Ordering Information