Emerson Rosemount 8732 Oxygen Equipment User Manual


 
Reference Manual
00809-0100-4665, Rev AA
August 2010
Rosemount 8732
F-2
26 DEVICE_MAN_ID Mapped to Mfg_ID parameter in
Manufacturing Block
27 DEVICE_ID Mapped to DEV_TYPE parameter in
Manufacturing Block
28 DEVICE_SER_NUM Mapped to last 16 characters of
DEVICE_ID_STRING parameter in
Manufacturing Block
29 DIAGNOSIS Detailed information of the device, bitwize
coded. More than one message is possible at
once. If MSB of byte 4 is set to 1 than more
diagnostic information is available in the
DIAGNOSIS_EXTENSION parameter.
30 DIAGNOSIS_EXTENSION Additional manufacturer-specific information
of the device, bitwize coded. More than one
message is possible at once.
31 DIAGNOSIS_MASK Supported std diagnostics
Warmstart
Coldstart
maint requd
ident number violation
function check
failed
maint demanded
extension available
32 DIAGNOSIS_MASK_EXTENSION Definition of supported
DIAGNOSIS_EXTENSION information-bits.
33 RESERVED
34 WRITE_LOCKING Software write protection.
0: acyclic write service of all parameter are
refused, except
WRITE_LOCKING and the TAB_ENTRY
parameter of the Linearization table, i.e.
access is denied.
2457: is the default value and means all
writable parameters of a device are writable.
35 FACTORY_RESET 1: (mandatory) is the command for resetting
device for default values. The setting of the
bus address is not affected.
2506: (optional) is the command for warmstart
of the device. All parametrisation remains
unchanged.
2712: (optional) The bus address to its default
address; other parametrisation remains
unchanged. The bus address is changed
immediately regardless if the
device is in cyclic data transfer state. The
reset is not suspended up to a subsequent
power cycle/warmstart.
36 DESCRIPTOR User-definable text (a string) to describe the
device within the application.
37 DEVICE_MESSAGE User-definable MESSAGE (a string) to
describe the device within the application or
in the plant.
38 DEVICE_INSTALL_DATE Date of installation of the device.
39 LOCAL_OP_ENA Local operation enable.
0: disabled (Local operation not allowed, i.e.
change of FB MODE from host
device only)
1: enabled (Local operation is allowed).
Index Parameter Description