Emerson Rosemount 8732 Oxygen Equipment User Manual


 
Reference Manual
00809-0100-4665, Rev AA
August 2010
4-5
Rosemount 8732
Run 8714i
Run the meter verification test to check the transmitter, sensor, or entire
installation.
Full Meter Verification
Run the internal meter verification to check the entire installation, sensor and
transmitter at the same time.
Transmitter Only
Run the internal meter verification to check the transmitter only.
Sensor Only
Run the internal meter verification to check the sensor only.
8714i Results
Review the results of the most recently performed 8714i Meter Verification
test. Information in this section details the measurements taken and if the
meter passed the verification test. For more details on these results and what
they mean, see Appendix C: Diagnostics.
Test Condition
Displays the conditions that the 8714i Meter Verification test was performed
under. For more details on this parameter see Appendix C: Diagnostics.
Test Criteria
Displays the criteria that the 8714i Meter Verification test was performed
against. For more details on this parameter see Appendix C: Diagnostics.
8714i Result
Displays the results of the 8714i Meter Verification test as pass or fail. For
more details on this parameter see Appendix C: Diagnostics.
Simulated Velocity
Displays the test velocity used to verify transmitter calibration. For more
details on this parameter see Appendix C: Diagnostics.
Actual Velocity
Displays the velocity measured by the transmitter during the transmitter
calibration verification test. For more details on this parameter see
Appendix C: Diagnostics.
Velocity Deviation
Displays the deviation of the transmitter calibration verification test. For more
details on this parameter see Appendix C: Diagnostics.
Transmitter Calibration Result
Displays the result of the transmitter calibration verification test as pass or fail.
For more details on this parameter see Appendix C: Diagnostics.
Sensor Calibration Deviation
Displays the deviation of the sensor calibration verification test. For more
details on this parameter see Appendix C: Diagnostics.