Rosemount 8732
www.rosemount.com
Appendix A Reference Data
Functional Specifications . . . . . . . . . . . . . . . . . . . . . . . . . page A-1
E-Series Advanced Diagnostics Capabilities . . . . . . . . . . page A-4
Output Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-4
Profibus PA fieldbus Digital Output Specifications . . . . . page A-4
Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . page A-6
Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-8
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-9
FUNCTIONAL
SPECIFICATIONS
Sensor Compatibility
Compatible with Rosemount 8705, 8711, 8721, and 570TM sensors.
Compatible with Rosemount 8707 sensor with D2 Dual calibration option.
Compatible with AC and DC powered sensors of other manufacturers.
Sensor Coil Resistance
350 maximum
Transmitter Coil Drive Current
500 mA
Flow Rate Range
Capable of processing signals from fluids that are traveling between 0.04 and
39 ft./s (0.01 to 12 m/s) for both forward and reverse flow in all sensor sizes.
Full scale continuously adjustable between –39 and 39 ft./s (–12 to 12 m/s).
Conductivity Limits
Process liquid must have a conductivity of 5 microsiemens/cm (5
micromhos/cm) or greater. Excludes the effect of interconnecting cable length
in remote mount transmitter installations.
Power Supply
90 -250 V AC, 50–60 Hz or 12-42 V DC
AC Power Supply Requirements
Units powered by 90-250 V AC have the following power requirements.