(Un\G166 to Un\G173) (Q68TD-G-H02 only)
When “Give value” (2H) is set in Conversion setting for disconnection detection
(Un\G164,Un\G165), the value to be stored into CH Measured temperature value
(Un\G11toUn\G18) can be set by user. (Refer to Section 3.2.2)
(1) Setting methods
(a) Set the value to be stored in buffer memory in units of 0.1 .
Settable range:-32768 to 32767
(b) Turn on Operating condition setting request (Y9) to activate the setting.
(2) Default value
All channels are set to “0”.
[Setting example] When the value of 800 is stored into CH1 Measured temperature
value for disconnection detection.
1) Set the following in buffer memory.
Conversion setting for disconnection detection (Un\G164):2
H
CH1 Conversion setting value for disconnection detection(Un\G166):8000
2) Turn on Operating condition setting request (Y9).
3.4.28 CH[ ] Conversion setting value for disconnection state
(Un\G166 to Un\G173) (Q68TD-G-H01only)
When “Give value” (2H) is set in the Disconnection state conversion setting
(Un\G164,Un\G165), the value to be stored into CH Measured temperature value
(Un\G11toUn\G18) can be set by user in the disconnection state check. (Refer to Section
3.2.3)
(1) Setting methods
(a) Set the valuetobe stored in buffer memory in units of 0.1 .
Settable range:-32768 to 32767
(b) Turn on Operating condition setting request (Y9) to activate the setting.
(2) Default value
All channels are set to“0”.
[Setting example] When the value of 800 is stored into CH1 Measured temperature
value for the check of disconnection state
1) Set the following in buffer memory.
Disconnection state conversion setting (Un\G164):2
H
CH1 Conversion setting value for disconnection state (Un\G166):8000
2) Turn on Operating condition setting request (Y9) to activate the setting.