Mitsubishi Q68TD-G-H01 Thermometer User Manual


 
3
SPECIFICATIONS
3.4 Buffer Memory
3.4.3 CH[ ] Time/Count/Moving average/Time constant setting (Un\G1 to Un\G8)
3 - 39
1
OVERVIEW
2
SYSTEM
CONFIGURATION
3
SPECIFICATIONS
4
SETUP AND
PROCEDURES BEFORE
OPERATION
5
UTILITY PACKAGE (GX
CONFIGURATOR-TI)
6
PROGRAMMING
7
ONLINE MODULE
CHANGE
8
TROUBLESHOOTING
3.4.3 CH[ ] Time/Count/Moving average/Time constant setting (Un\G1 to
Un\G8)
When the averaging processing (1H to 4H) is specified with Averaging processing
selection (Un\G24, Un\G25), time average, count average, moving average or time
constant for primary delay filter is set. (Refer to Section 3.2.1)
(1) Setting methods
(a) Set the following setting range in buffer memory.
* 1 Set the values in units of 320ms.
For the details of the setting values, refer to Section 3.2.1 (3) Averaging processing or Section
3.2.1 (4) Primary delay filter.
(b) Turn on Operating condition setting request (Y9) to activate the setting. (Refer to
Section 3.3.2)
(2) Default value
All channels are set to “0”.
POINT
(1) When a value out of the setting range in Table 3.10 is written, an error occurs
and the following also occurs.
The error codes (20 , 30 , 31 , 32 ) are stored to the error code
(Un\G19). (Refer to Section 8.1)
Error flag (XF) turns on.
Conversion processing is performed with the setting before the error
occurence.
(2) When a value is set on the channels set sampling processing (0
H) to
Averaging processing selection (Un\G24, Un\G25), the setting value of CH
Time/Count/Moving average/Time constant setting (Un\G1 to Un\G8) is
ignored.
Table 3.10 Settable range
Processing method Setting value
Time average
1280 to 5000(ms)
*1
Count average 4 to 500(times)
Moving average 2 to 60(times)
Primary delay filter
320 to 5000(ms)