Mitsubishi Q68TD-G-H01 Thermometer User Manual


 
3 - 36
3.4 Buffer Memory
3.4.1 Buffer memory assignment
3
SPECIFICATIONS
BE
H
190
CH1 Factory default offset value
*3
0
R/W
*2
Section 3.4.29
BF
H
191
CH1 Factory default gain value
*3
0
R/W
*2
C0
H
192
CH1 User range settings offset value
*3
0
R/W
*2
C1
H
193
CH1 User range settings gain value
*3
0
R/W
*2
C2
H
194
CH1 User range settings thermal EMF offset value(L)
*3
0
R/W
*2
C3
H
195
CH1 User range settings thermal EMF offset value(H)
*3
C4
H
196
CH1 User range settings thermal EMF gain value(L)
*3
0
R/W
*2
C5
H
197
CH1 User range settings thermal EMF gain value(H)
*3
C6
H
198
CH2 Factory default offset value
*3
0
R/W
*2
C7
H
199
CH2 Factory default gain value
*3
0
R/W
*2
C8
H
200
CH2 User range settings offset value
*3
0
R/W
*2
C9
H
201
CH2 User range settings gain value
*3
0
R/W
*2
CA
H
202
CH2 User range settings thermal EMF offset value(L)
*3
0
R/W
*2
CB
H
203
CH2 User range settings thermal EMF offset value(H)
*3
CC
H
204
CH2 User range settings thermal EMF gain value(L)
*3
0
R/W
*2
CD
H
205
CH2 User range settings thermal EMF gain value(H)
*3
CE
H
206
CH3 Factory default offset value
*3
0
R/W
*2
CF
H
207
CH3 Factory default gain value
*3
0
R/W
*2
D0
H
208
CH3 User range settings offset value
*3
0
R/W
*2
D1
H
209
CH3 User range settings gain value
*3
0
R/W
*2
D2
H
210
CH3 User range settings thermal EMF offset value(L)
*3
0
R/W
*2
D3
H
211
CH3 User range settings thermal EMF offset value(H)
*3
D4
H
212
CH3 User range settings thermal EMF gain value(L)
*3
0
R/W
*2
D5
H
213
CH3 User range settings thermal EMF gain value(H)
*3
D6
H
214
CH4 Factory default offset value
*3
0
R/W
*2
D7
H
215
CH4 Factory default gain value
*3
0
R/W
*2
D8
H
216
CH4 User range settings offset value
*3
0
R/W
*2
D9
H
217
CH4 User range settings gain value
*3
0
R/W
*2
DA
H
218
CH4 User range settings thermal EMF offset value(L)
*3
0
R/W
*2
DB
H
219
CH4 User range settings thermal EMF offset value(H)
*3
DC
H
220
CH4 User range settings thermal EMF gain value(L)
*3
0
R/W
*2
DD
H
221
CH4 User range settings thermal EMF gain value(H)
*3
DE
H
222
CH5 Factory default offset value
*3
0
R/W
*2
DF
H
223
CH5 Factory default gain value
*3
0
R/W
*2
E0
H
224
CH5 User range settings offset value
*3
0
R/W
*2
E1
H
225
CH5 User range settings gain value
*3
0
R/W
*2
E2
H
226
CH5 User range settings thermal EMF offset value(L)
*3
0
R/W
*2
E3
H
227
CH5 User range settings thermal EMF offset value(H)
*3
E4
H
228
CH5 User range settings thermal EMF gain value(L)
*3
0
R/W
*2
E5
H
229
CH5 User range settings thermal EMF gain value(H)
*3
E6
H
230
CH6 Factory default offset value
*3
0
R/W
*2
E7
H
231
CH6 Factory default gain value
*3
0
R/W
*2
E8
H
232
CH6 User range settings offset value
*3
0
R/W
*2
E9
H
233
CH6 User range settings gain value
*3
0
R/W
*2
EA
H
234
CH6 User range settings thermal EMF offset value(L)
*3
0
R/W
*2
EB
H
235
CH6 User range settings thermal EMF offset value(H)
*3
EC
H
236
CH6 User range settings thermal EMF gain value(L)
*3
0
R/W
*2
Table 3.9 Buffer memory assignment
Addresses
Description Default value
Read/Write
*1
Reference
section
Hex. Dec.